Heptafluoropropane, also called heptafluoropropane, FM2, HFC-2or HFC-227ea ( ISO name), as well as apaflurane ( INN ), is a colourless, odourless gaseous halocarbon commonly used as a gaseous fire suppression agent. By definition, an automatic fire suppression system can operate without human intervention. In many systems, detection is accomplished by mechanical or electrical means. HFC-227ea has a zero ozone depleting potential, a low global warming potential, and a short atmospheric lifetime.
It is particularly useful where an environmentally acceptable agent is essential, where clean up of other media presents a problem,.
Gaseous fire suppression, also called clean agent fire suppression, is a term to describe the use of inert gases and chemical agents to extinguish a fire. The system typically consists of the agent, agent storage containers, agent release valves, fire detectors, fire detection system, agent. Our Clean Agent Fire Protection System, which includes the use of HFC-227ea and FM-20 leaves no residue and doesn’t require costly clean-up, unlike sprinklers and other fire protection systems. The typical concentration of an FM2system is normally between 7. It is generally used in situations where water from a fire sprinkler would damage expensive equipment or where water-based fire protection is.
It was a critical and commercial success, running for 8performances in New York and 3in London, with tours by several road companies. This standard contains minimum requirements for total flooding and local application clean agent fire extinguishing systems.
It does not cover fire extinguishing systems that use carbon dioxide or water as the primary extinguishing media, which are addressed by other NFPA documents. Since its discovery, it is accepted and respected worldwide due to its remarkable work of protecting some of the most irreplaceable and critical assets around the world. Agent – FM-2(HFC-227ea) is a clean, gaseous agent containing no particles or oily residues.
FM-2leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. Use extinguishing agent appropriate to other materials involved. Keep containers and surroundings cool with water spray as containers may rupture or burst in the heat of a fire. STABILITY AND REACTIVITY Reactivity : Decomposes on heating. Chemical stability : Stable at normal temperatures and storage conditions.
Possibility of hazardous reactions : Polymerization will not occur. We also provide Fire alarm, fire suppression systems and fire extinguisher installation, inspections and maintenance in Toronto. FM2is a waterless fire protection system, it is discharged into the risk within seconds and suppresses the fire immediately. Local embassy – For -related communication in languages other than English. Reference desk – Serving as virtual librarians, volunteers tackle your questions on a wide range of subjects.
Site news – Announcements, updates, articles and press releases on and the media Foundation. FM-2’s physical properties lower the flame temperature, while the chemical action suppresses flame propagation.
In fact, FM-2is the appropriate choice in applications where liquid extinguishants, water-based or dry chemical products can cause costly damage or result in considerable and expensive downtime. FM-2Discharge is an excellent fire suppression system that will disperse the chemical FM-20 also known as heptafluoropropane, automatically when smoke detectors become activated by the presence of fire. Please take a few minutes to complete our survey. Your responses will help us to better understand and meet your needs. Refilling an FM2is a cheap and easy process, meaning that there’s not as much disruption and downtime for your business.
The use of FM2within an occupied space is perfectly safe. Resolution : Please check box if Material and Concentration is entered Manually. FM-2is used as an extinguishing agent and therefore is not a problem when trying to control a blaze. Containers may explode in heat of fire.
Leakage Through Raised Floor Tiles: The leakage by diffusion through the tiles of the raised roof floor is considered only when the raised floor of the room in isolation is protected by FM 200. When both the room and the raised floor are protected by FM 20 such leakage through the raised floor is not to be considere. Fireboy-Xintex provides a variety of reliable, trouble-free fire detection, fire suppression and gas detection products.
Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressure-related explosions and industrial fire hazards.
No comments: