Unconditioned spaces in hot and humid climates are of particular concern, though these practices should be applied everywhere.
The pipe insulators work was not great ( insulating chilled water pipes must be done very carefully with attentions to details: insulate valve and valve handles, insulate stem of thermometers and gauges etc.). In some areas the other trades used the insulated pipes instead of ladders. This damages the thin vapor barrier.
The interaction between chilled water systems and the ambient air around the pipes can cause condensation on the pipes. Incorrect product selection or using untrained installers can cause a building owner’s life-cycle costs to increase by millions of dollars compared to the minor cost premium of correctly insulating the pipe. A successful chilled water insulation material must provide high-energy efficiency, condensation control, and Browse Insulation Jacketing Datasheets for Polyguard Products, Inc.
Below-ambient piping in a chilled water system is a very demanding insulation application as a result of the strong vapor drive towards the cold pipe , particularly in high humidity conditions. Cooling systems and insulation thickness. The insulation thickness of chilled water , refrigerant and brine systems should not be less than indicated below.
XPS (extruded polystyrene) is a closed cell rigid foam insulation for low temperature (168°F) pipe insulation systems for chilled water and refrigeration. The R-value (thermal resistance), compressive strength, moisture, etc. New Pipe Insulation Thicknesses. For many of the steam heating distribution pipes in buildings, with an operating temperature greater than 350°F, in. What insulation should you use for a cold water pipe?
Should I insulate my cold water pipes? How to insulate hot and cold water pipes? Can we use copper pipe for chilled water system? Thermal Insulation for pipe s, ducts and equipment. This, in turn, can lead to a host of other problems, including corrosion, insulation damage, mold and fungus growth, and in extreme cases cracked and leaking pipes.
Polyisocyanurate’s water absorption and water vapor transmission properties are far better than fiberglass or XPS, and approach those of cell glass. Dyplast’s ISO-Cis generally the most cost-effective insulation for chilled water and refrigeration systems - both from an installed cost and long-term system efficiency. Cellular glass, glass fiber, phenolic foam, and polyurethane foam are popular materials for insulating chilled - water pipe. As tests I recently concluded confirm, in hot, humid climates, there are significant differences in thermal performance over time between them.
Chilled Water Pipe Insulation Systems. Piping that carries water at below-ambient temperatures creates a strong vapor drive toward the pipe. In other words, ambient air — which is at higher vapor pressure — tries to push moist air toward the insulated pipe surface, where vapor pressure is lower.
Domestic cold water pipes must be insulated using preformed PIR sheaths covered with a sheet of hard PVC.
The thickness of the insulation must be identical to that used for chilled water pipes. A green sleeve must be glued to the end of each domestic cold water supply pipe (see Photo 6). This guide covers the installation requirements for insulation of chilled service piping and vessel systems operating between 32°F and 167°F.
This guide is applicable to PermaTherm’s 4chilled water pipe insulation. Apply approved adhesive in longitudinal seam and end faces of the insulation and entire pipe surfaces. Ensure pipe surface are clean prior to application of adhesive.
Apply insulation with longitudinal seams at top of horizontal pipe runs.